Matched and Mismatched Termination

Оглавление

The input impedance at any location on a line is Zin (x) = Z0 if it is matched terminated in its characteristic impedance, i.e. ZL = Z0. Normally, the characteristics impedance of a microwave line is a real quantity. The line terminated in Z0 does not create any reflected wave on a transmission line. However, for the mismatched termination ZL ≠ Z0, there is a reflected wave on a transmission line, traveling from the load end to the source end.