For the port‐2 open‐circuited, I2 = 0. The voltage at the port‐1 is


Likewise, for the port‐1 open‐circuited, I1 = 0, and the parameters are Z22 = ZB + ZC, Z12 = ZC. The [Z] matrix description of a T‐network is

(3.1.7)


Figure 3.2 Lumped T‐network.

The given circuit is asymmetrical. However, it is a reciprocal circuit. It becomes symmetrical for ZA = ZB.