Читать книгу Hydraulic Fluid Power - Andrea Vacca - Страница 85
Example 4.3 Orifice as a Metering Element or a Compensator
ОглавлениеThe system in figure consists of a fixed displacement pump and a variable orifice in parallel with a pressure relief valve. The pressure relief valve limits the maximum pressure at the pump outlet to p*. The pump delivers a fixed flow rate QP independently of the pump outlet pressure. Find the flow rate through the orifice, QO, as well as the pump outlet pressure pP, as a function of the orifice area opening, Ω. Describe also the function of the orifice, which can either be metering or compensator.
Given:
The pump flow rate, QP; the setting of the relief valve p*.
Find:
1 The flow rate through the orifice, QO
2 The pressure at pump outlet, pP
3 The orifice function (metering/compensator)