metrological traceability – метрологическая прослеживаемость – метрологиялық бақылау

core сoncept – основное понятие – негізгі түсінік

to establish – устанавливать – құру, қою; орнату, орналасу

property – свойство – қасиет

value – значение – мән; мағына

reference – эталон – эталон, үлгі, өлшем

standard – стандарт – стандарт

to perform – осуществлять, проводить – істеу; жүзеге асыру, іске асу

measuring instrument – измерительный прибор – өлшеуіш аспап

range – диапазон – ауқым

quality – качество – сапа; қасиет

quality management system – система управления качеством – сапаны басқару жүйесі

accuracy – правильность – ұқыптылық; дұрыстық

systematic bias – систематическая ошибка – жүйелі қате

precision – точность – дәлдік; бірдейлік

evaluation – оценка – бағалау, баға кесу; баға

primary standard – первичный стандарт – алғашқы стандарт

error – погрешность, серьезная ошибка – қате, адасу, жаңылу, маңызды қате

ratio – соотношение – қатыс, арақатынас, өзара қатынас; байланыс

previous – предыдущий – бұдан бұрынғы, осыдан ілгері, өткен

comparability – сопоставимость – салыстыру

to use – использовать – пайдалану

equipment – оборудование – жабдық

voltmeter – вольтметр – вольтметр

triple point – тройная точка – үштік нүкте

specimen – образец – үлгі

X-rays – рентгеновские лучи – рентгендік сәулелер

electron beam – пучок электронов – электрондар шоғы

to read – показывать – көрсету; әйгілеу; байқату; таныту; білдіру

constant – постоянный – тұрақты; бірқалыпты, өзгермейтін

to verify – проверять – тексеру, қарап шығу; сынап байқау

to adjust – устанавливать (прибор) – (аспапты) орнату, орналастыру

to allow for – предусматривать – алдын ала ескеру; назарда ұстау

to settle – устанавливать – қоныстану, орналасу; ретке келтіру

distinction – различие – айырма; ерекшелік

inexact – неточный – дәл емес

critical part – важная часть – маңызды бөлім

measurement uncertainty – погрешность измерений – өлшем қателігі

to reserve for – предназначать – арнау, белгілеу; жарату; тағайындау

lead – провод – бастау, көрсету; алып жүру; апару

establishment – установление – орнату

Ex. 1. Read and translate the text

Metrological traceability

A core concept in metrology is metrological traceability, defined by the BIPM as «the property of the result of a measurement or the value of a st andard whereby it can be related to stated references, usually national or international standards, through an unbroken chain of comparisons, all having stated uncertainties)). The level of traceability establishes the level of comparability of the measurement: whether the result of a measurement can be compared to the previous one, a measurement result a year ago, or to the result of a measurement performed anywhere else in the world.

Traceability is most often obtained by calibration, establishing the relation between the indication of a measuring instrument and the value of a measurement standard. These standards are usually coordinated by national metrological institutes: National Institute of Standards and Technology, National Physical Laboratory, UK, etc. Traceability is used to extend measurement from a method that works in one regime to a different method that works in a different regime. An example would be the measurement of the spacing of atomic planes in the same crystal specimen using both X-rays and an electron beam. Traceability also refers to the methodology used to calibrate various instruments by relating them back to a primary standard. Traceability, accuracy, precision, systematic bias, evaluation of measurement uncertainty are critical parts of a quality management system. Mistakes can make measurements and counts incorrect. Even if there are no mistakes, nearly all measurements are still inexact. The term «error» is reserved for that inexactness, also called measurement uncertainty. Among the few exact measurements are:

– The absence of the quantity being measured, such as a voltmeter with its leads shorted together: the meter should read zero exactly.

– Measurement of an accepted constant under qualifying conditions, such as the triple point of pure water: the thermometer should read 273.16 Kelvin (0.01 degrees Celsius, 32.018 degrees Fahrenheit) when qualified equipment is used correctly.

– Self-checking ratio metric measurements, such as a potentiometer: the ratio in between steps is independently adjusted and verified to be beyond influential inexactness.

All other measurements either have to be checked to be sufficiently correct or left to chance. Metrology is the science that establishes the correctness of specific measurement situations. This is done by anticipating and allowing for both mistakes and error. The precise distinction between measurement error and mistakes is not settled and varies by country. Calibration is the process where metrology is applied to measurement equipment and processes to ensure conformity with a known standard of measurement, usually traceable to a national standards board.

Ex. 2. Answer the questions

1. What is metrological traceability ?

2. What does the level of comparability of the measurement mean?

3. What are the critical parts of management quality system ?

4. What is the term «error» reserved for ?

5. What organizations coordinate standards ?

Ex. 3. Are these sentences true or false ?

1. Traceability is most often obtained by evaluation.

2. Metrological traceability was defined by the UN.

3. Metrological traceability is a core concept in metrology.

4. All other measurements either have to be checked to be sufficiently correct or left to chance.

5. Errors can make measurements and counts incorrect.

6. The precise distinction between measurement error and mistakes has been already settled.

7. Calibration is a process where metrology is not applied to measurement equipment.

Ex. 4. Fill the blanks using the following words: establishment, instrument, correctness, to achieve, calibration, term, standard, metrological, key

Metrological traceability is a … concept. This … was introduced by the BIMP. Metrological traceability allows establishing the … of the obtained measurement result and the correspondence of this result with the national … The accuracy of the measurement result is by … the comparability with the previous results obtained earlier. Traceability is obtained by … Calibration means the … of the relation between the indication of a measuring … and the value of a measurement standard. These standards are coordinated by national … institutes.

Ex. 5. Match the beginning with the endings based on the text


Ex. 6. Put the question to the bold-typed words:

1. This method works in one regime.

2. National metrological institutes coordinate standards.

3. The level of traceability establishes the level of comparability of the measurement.

4. New measurement result is compared with the previous measurement result.

5. To establish the precision of the obtained result we must compare it with the previous one.

Ex. 7. Make the summary of the text: «Metrological traceabi- lity», using the following plan:

The definition of metrological traceability;

The way of obtaining metrological traceability;

The spheres of the use of metrological traceability.

Grammar and spelling quiz

Find and correct the grammar and spelling mistakes in the following passages a) Scientific metrology

Scientific metrology are an uantity of metrology. It deal of the establishmen of uantity system, unit system. Scientific metrology develop new methods of measurement. S cientific metrology are called also fundamental metrology. It help to implement all of the measurement standards into practice. Scientifc metrology transfer traceability from the standards to in society users. This sub field of metrology play a important role in society life.

b) What is traceability?

Traceability is o btained by calibration often. Calibration establishe t he relation between the indication of an m easuring instrument and an value of a measurement standart. These standards is u sually coordinated with n ational metrological institutes: National Institute of Standards and Technology, National Physical Laboratory, UK, etc. Traceability are use to extended measurement from a method that work in one regime to a different method who work in a diferent regime. An example would be the measurement of the spacing of atomic planes in the same crystal specimen using both x-rays and an beam electron.

Методическая разработка по английскому языку по специальности «Стандартизация, сертификация и метрология»