4.5 Results Analysis under a Balanced System
ОглавлениеThe proposed system is analyzed under a balanced system condition that considers linear, nonlinear, and induction motor loads for demonstrating the performance on harmonic eliminations. The system is analyzed for source voltage (Vs), terminal voltage (Vt), source current (Is), compensating current (Ic), load currents (Il), battery voltage (Vbb), and battery current (Ibb) based signals. The parameters under the system consideration are as follows:
Source: Vpeak = 415 V, 3-Phase, 50 Hz
Linear load: Resistiveload = 1000 Ω, Inductiveload = 1e−3H
Nonlinear load: Rectifier-based inductive load with Rload = 1000 Ω, Lload = 1e−3H
Induction motor load: Nominal power = 3730VA, 415 V, 50 Hz and Tm = 10, hysteresis controller band 0.1
Battery and controller parameter: VOC = 720 V, Rb1 = 0.1 Ω, Rb2 = 1000 Ω, Cb2 = 1688 F, Cdc = 5000 F, I*smd = 35
PI controller: Proportional constant = 043, Integrator constant = 0.15