1.5.1 Optimum Placement of RDGs and Shunt Capacitors to 33-Bus Distribution Network

Оглавление

In this section, the optimum placement of biomass DG, solar PV, and shunt capacitors, to the 33-bus distribution network is discussed. Table 1.6 presents the optimum sizes and locations of biomass DG, solar PV, and shunt capacitors for different load hours of the 33-bus distribution networks. The reductions of active power loss and VDI for different load hours have been shown in Figures 1.3 and 1.4, respectively. From Table 1.6 and Figure 1.3, it may be noticed that the active power loss reduction after the placement of biomass DG, solar PV, and shunt capacitor is quite significant for all the load hours. After the placement of RDGs and shunt capacitors to bus numbers 14, 31, and 30, respectively, the active power loss of the 33-bus distribution network reduces from 202.6771 kW to 36.8247 kW for the 15th load hour. It may also be noticed that in presence of solar radiation, the active power loss reduction is higher compared to the same when the solar power generation is less or absent.

From Table 1.6 and Figure 1.4, it may be noticed that the improvement of the voltage profile of the 33-bus distribution network is very good for all the load hours of the day. Improvement of the voltage profile of the distribution network leads to the reduction of VDI. From Table 1.6 and Figure 1.4, the reduction of the VDI for all the load hours of the day may be noticed quite prominently. The voltage profile before and after the placement of DG to the 33-bus distribution network, for the 15th load hour, has been presented in Figure 1.5.

Table 1.6 Optimum placement of RDGs and shunt capacitors to the 33-bus distribution network.

Load hour Optimum size of biomass DG (kW) Optimum size of solar PV (kW) Optimum size of shunt capacitor (kVAr) Active power loss before placement of DG (kW) Active power loss after placement of DG (kW) Base VDI (before placement of DG) VDI after placement of DG
Location – 14 Location - 31 Location - 30
1 621.5083 1759.48 800 78.6548 29.4379 0.0453 0.0037
2 586.0025 1759.48 750 68.7376 25.8221 0.0396 0.0032
3 568.0646 1759.48 725 64.0501 24.1064 0.0369 0.003
4 550.005 1759.48 700 59.5413 22.4517 0.0343 0.0028
5 550.005 1759.48 700 59.5413 22.4517 0.0343 0.0028
6 568.0646 1759.48 725 64.0501 24.1064 0.0369 0.003
7 617.4665 1759.48 800 78.6548 28.7562 0.0453 0.0036
8 671.2714 1759.48 925 112.8660 31.2546 0.0651 0.0039
9 683.3 1759.48 1025 150.3564 30.2443 0.0868 0.0035
10 685.9 1759.48 1125 181.4934 31.9668 0.1048 0.0035
11 687.6 1759.48 1150 198.3321 33.0856 0.1146 0.0036
12 667.5 1759.48 1175 202.6771 32.981 0.1171 0.0033
13 661.5 1759.48 1150 198.3321 32.0711 0.1146 0.0032
14 683.7 1759.48 1175 202.6771 33.5922 0.1171 0.0035
15 730.9 1759.48 1175 202.6771 36.8247 0.1171 0.0043
16 752.1 1759.48 1175 189.8051 39.7576 0.1096 0.0048
17 812.9 1759.48 1175 185.6225 50 0.1072 0.0066
18 866.0 1759.48 1225 185.6225 63.9226 0.1072 0.0086
19 861.3 1759.48 1175 173.3949 63.4637 0.1001 0.0087
20 851.4 1759.48 1175 169.4248 62.2863 0.0978 0.0083
21 851.4 1759.48 1175 169.4248 62.2863 0.0978 0.0083
22 861.3 1759.48 1175 173.3949 63.4637 0.1001 0.0087
23 813.6 1759.48 1100 150.3564 55.3269 0.0868 0.0074
24 691.0056 1759.48 900 100.7052 37.4156 0.0580 0.0048

Figure 1.3 Variation of active power loss before and after placement of DGs to the 33-bus distribution network.


Figure 1.4 Variation of VDI before and after placement of DGs to the 33-bus distribution network.


Figure 1.5 Voltage profile of the 33-bus distribution network before and after placement of DGs for 15th load hour.