Читать книгу Fundamentals of Fixed Prosthodontics - James C. Kessler - Страница 78
Facebow record technique
ОглавлениеA sheet of baseplate wax is softened in hot water, and the bite fork is completely covered with it. The wax-covered bite fork is positioned against the maxillary teeth, and the patient is instructed to close until the mandibular teeth contact the wax on the underside of the fork. The shaft of the bite fork will be to the left of the patient’s midline.
The wax is cooled in the mouth with an air syringe. The fork is removed from the mouth and placed in a bowl of cold tap water to finish cooling. Excess wax and any areas imprinted by soft tissue are trimmed off. The maxillary cast is seated in the wax record to be sure that it is stable. If there is any rocking of the cast, the occlusal surfaces of the cast should be checked for nodules of stone. If there are none, either the cast or the record is distorted and must be remade.
If the bite fork assembly is separate from the facebow, the transfer (vertical) rod of the assembly is inserted into the bow socket on the underside of the black centerpiece on the front of the facebow. The flat surface on the rod must be in front when it is placed in the socket. The assembly should be on the right, with the knobs facing the front (Fig 5-57). The thumbscrew is tightened on the front of the centerpiece.
While the patient grips the bite fork between the maxillary and mandibular teeth, the loosened bite fork clamp is positioned 4 cm (1.5 inches) over the bite fork shaft. The facebow should be pointed upward during this action (Fig 5-58). The bow is opened by pulling outward on the arms and is swung down into position, with an earpiece placed gently into each external auditory meatus. The patient is instructed to adjust the earpieces to the most comfortable seated position (Fig 5-59).
Fig 5-58 The bite fork clamp is slid onto the shaft.
Fig 5-59 The patient should adjust the facebow for comfort. The earpieces should be checked to make sure they are still seated.
Fig 5-60 The infraorbital notch (orbitale) is located and marked.
Fig 5-61 The pointer is rotated toward the reference mark.
Fig 5-62 The bow is secured with one hand while the other tightens the thumbscrews on the bite fork assembly.
Fig 5-63 The thumbscrews are tightened in the order indicated (1–3).
The orbitale (infraorbital notch) is marked on the patient’s face with a felt-tip marker to provide an anterior reference point (Fig 5-60). The thumbscrew that holds the orbital pointer is loosened and gently swung in toward the reference mark (Fig 5-61). The front of the facebow is elevated along the transfer (vertical) rod of the bite fork assembly until the pointer is at the plane of the anterior reference point. The bow is grasped to resist torquing (Fig 5-62), and the three thumbscrews are tightened in order from left to right (Fig 5-63):
1 Transfer (vertical) rod/transverse (horizontal) rod
2 Transverse rod clamp (upper)
3 Bite fork clamp (lower)
They must be tight; an Allen wrench can be used to tighten them if necessary.
The reference pointer is rotated back over the right temple of the bow, and the thumbscrew is tightened enough to hold it there. While the patient opens, the ends of the bow are grasped, and the earpieces are removed from the auditory meati. It should be held firmly because the bow is made of spring steel and could snap back. The bow is slid away from the patient. The facebow, earpieces, and bite fork are disinfected with a hospital-grade disinfectant before continuing.
Fig 5-64 Before the facebow is attached, the condylar inclination is set at 30 degrees.
Fig 5-65 The Bennett angle ring is rotated to 30 degrees.
Fig 5-66 The maxillary cast is oriented to the articulator by the bite fork assembly in the mounting guide.
The reference pointer is rotated back over the right temple of the bow, and the thumbscrew is tightened enough to hold it there. While the patient opens, the ends of the bow are grasped, and the earpieces are removed from the auditory meati. It should be held firmly because the bow is made of spring steel and could snap back. The bow is slid away from the patient. The facebow, earpieces, and bite fork are disinfected with a hospital-grade disinfectant before continuing.