Example 1.5 Heat Exchanger with Feed Seawater
ОглавлениеAn adiabatic heat exchanger provides thermal load to feed seawater, such that feed seawater can be supplied to MEE desalination system at 70 °C.
Steam stream: 1 kg/s, 120 °C
State 1: saturated vapor
State 2: saturated liquid
Feed seawater stream:
State 3: 20 °C
State 4: 70 °C
xf = 40 000 ppm
Find:
1 Feed seawater flow rate.
2 Assume feed is fresh water, find feed flow rate.
3 If steam (thermal load) is generated by conventional boiler using natural gas as a fuel, find fuel flow rate and emitted amount of CO2.
4 Provide emission table for three types of fuels to generate steam (thermal load).