Читать книгу Agitator Design for Gas-Liquid Fermenters and Bioreactors - Gregory T. Benz - Страница 43
Aeration Number
ОглавлениеAeration number, also called gas flow number, is the ratio of actual gas flow rate at the impeller (corrected for absolute pressure and temperature) divided by the impeller diameter cubed and the shaft speed:
(3.7)
This group is used for power draw calculations in the gassed condition, along with other dimensionless groups. It can be thought of, in a way, as being proportional to the ratio of gas flow rate to the impeller pumping capacity.