If τ*N =10, τ = 10/N = 10/30(1/min) = 1/3 min = 20 s. Note that one can use any units for shaft speed; the resultant blend time units will be determined by this. Note also that as long as the dimensionless blend time is fixed, the result is independent of tank size. This means, for a given D/T and Reynolds number, the blend time at 30 rpm will be the same in any size tank. However, the P/V goes up exponentially when trying to keep the same D/T and the same shaft speed. So, designing for the same blend time in a large tank as a small one can be problematic.