Читать книгу Process Intensification and Integration for Sustainable Design - Группа авторов - Страница 52
Appendix B: Key Parameters for the Turboexpander Process
Оглавление2.B
Table 2.B.1 Demethanizer column parameters.
| Column | Total feed flow rate (MMSCFD) | T (°F) | P (psig) | Number of trays | Light/heavy key |
| Demethanizer | 202 | −111 to 65.4 | 250–254 | 10 | Methane/ethane |
Feed flow rate is a standard vapor volumetric flow rate.
Table 2.B.2 Low temperature separator (LTS) inlet temperature.
| Stream | T (°F) |
| 10 | −25 |
Table 2.B.3 Outlet pressure for the pressure changing equipment.
| Stream | P (psig) |
| 13 | 250 |
| 14 | 255 |
| 21 Residue gas | 900 |