Читать книгу Process Intensification and Integration for Sustainable Design - Группа авторов - Страница 53

Appendix C: Key Parameters for the Fractionation Train

Оглавление

2.C

Table 2.C.1 Fractionation train column parameters for the base case (Feed #3).

Column Feed flow rate (MMSCFD) T (°F) P (psig) Number of trays Light/heavy key
Deethanizer 27.1 38.8–159 285–292 35 Ethane/propane
Depropanizer 17.9 104–187 190–193 36 Propane/i‐butane
Debutanizer 8.09 163–219 135–140 60 n‐Butane/pentane
C4 splitter 5.74 147–179 120–140 60 i‐Butane/n‐butane

Feed flow rate is a standard vapor volumetric flow rate.

Process Intensification and Integration for Sustainable Design

Подняться наверх