Читать книгу Advances in Hearing Rehabilitation - Группа авторов - Страница 58

References

Оглавление

1Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, et al: Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1–132.

2Håkansson B, Tjellström A, Rosenhall U, Carlsson P: The bone-anchored hearing aid. Principal design and a psychoacoustical evaluation. Acta Otolaryngol 1985;100:229–239.

3von Békésy G: Experiments in Hearing. New York, NY, McGraw-Hill, 1960.

4Reinfeldt S, Håkansson B, Taghavi H, Eeg-Olofsson M: New developments in bone-conduction hearing implants: a review. Med Devices (Auckl) 2015;8:79–93.

5Colquitt JL, Jones J, Harris P, Loveman E, Bird A, Clegg AJ, et al: Bone-anchored hearing aids (BAHAs) for people who are bilaterally deaf: a systematic review and economic evaluation. Health Technol Assess 2011;15:1–200, iii-iv.

6Flynn MC: Smart and Small – Innovative Technologies Behind the Cochlear™ Baha® 5 Sound Processor, 2016.

7McDermott AL, Dutt SN, Reid AP, Proops DW: An intra-individual comparison of the previous conventional hearing aid with the bone-anchored hearing aid: the nijmegen group questionnaire. J Laryngol Otol Suppl 2002;116:15–19.

8Olsen SØ, Glad H, Nielsen LH: Comparison of two bone anchored hearing instruments: BP100 and Ponto Pro. Int J Audiol 2011;50:920–928.

9Sprinzl G, Lenarz T, Ernst A, Hagen R, Wolf-Magele A, Mojallal H, et al: First European multicenter results with a new transcutaneous bone conduction hearing implant system: short-term safety and efficacy. Otol Neurotol 2013;34:1076–1083.

10Barbara M, Perotti M, Gioia B, Volpini L, Monini S: Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a first series of patients with mixed hearing loss. Acta Otolaryngol 2013;133:1058–1064.

11Riss D, Arnoldner C, Baumgartner WD, Blineder M, Flak S, Bachner A, et al: Indication criteria and outcomes with the bonebridge transcutaneous bone-conduction implant. Laryngoscope 2014;124:2802–2806.

12Ihler F, Volbers L, Blum J, Matthias C, Canis M: Preliminary functional results and quality of life after implantation of a new bone conduction hearing device in patients with conductive and mixed hearing loss. Otol Neurotol 2014;35:211–215.

13Medtronic: Bone Conduction Hearing Devices (BAHA) by Sophono. 2016;1.

14Siegert R, Kanderske J: A new semi-implantable transcutaneous bone conduction device: clinical, surgical, and audiologic outcomes in patients with congenital ear canal atresia. Otol Neurotol 2013;34:927–934.

15Sylvester DC, Gardner R, Reilly PG, Rankin K, Raine CH: Audiologic and surgical outcomes of a novel, nonpercutaneous, bone conducting hearing implant. Otol Neurotol 2013;34:922–926.

16Briggs R, Van Hasselt A, Luntz M, Goycoolea M, Wigren S, Weber P, et al: Clinical performance of a new magnetic bone conduction hearing implant system: results from a prospective, multicenter, clinical investigation. Otol Neurotol 2015;36:834–841.

17Wazen JJ, Gupta R, Ghossaini S, Spitzer J, Farrugia M, Tjellstrom A: Osseointegration timing for Baha system loading. Laryngoscope 2007;117:794–796.

18Hol MK, Nelissen RC, Agterberg MJ, Cremers CW, Snik AF: Comparison between a new implantable transcutaneous bone conductor and percutaneous bone-conduction hearing implant. Otol Neurotol 2013;34:1071–1075.

19Feddersen WE, Sandel TT, Teas DC, Jeffress LA: Localization of high-frequency tones. J Acoust Soc Am 1957;29:988–991.

20Stenfelt S, Zeitooni M: Binaural hearing ability with mastoid applied bilateral bone conduction stimulation in normal hearing subjects. J Acoust Soc Am 2013;134:481–493.

21Priwin C, Stenfelt S, Granström G, Tjellström A, Håkansson B: Bilateral bone-anchored hearing aids (BAHAs): an audiometric evaluation. Laryngoscope 2004;114:77–84.

22Hamann C, Manach Y, Roulleau P: [Bone anchored hearing aid. Results of bilateral applications]. Rev Laryngol Otol Rhinol (Bord) 1991;112:297–300.

23Bosman AJ, Snik AF, van der Pouw CT, Mylanus EA, Cremers CW, et al.: Audiometric evaluation of bilaterally fitted bone-anchored hearing aids. Audiology 2001;40:158–167.

24Priwin C, Jönsson R, Hultcrantz M, Granström G: BAHA in children and adolescents with unilateral or bilateral conductive hearing loss: a study of outcome. Int J Pediatr Otorhinolaryngol 2007;71:135–145.

25Jerger J, Brown D, Smith S: Effect of peripheral hearing loss on the masking level difference. Arch Otolaryngol 1984;110:290–296.

26Snik AF, Beynon AJ, Mylanus EA, van der Pouw CT, Cremers CW: Binaural application of the bone-anchored hearing aid. Ann Otol Rhinol Laryngol 1998;107:187–193.

27Dun CA, de Wolf MJ, Mylanus EA, Snik AF, Hol MK, Cremers CW: Bilateral bone-anchored hearing aid application in children: the Nijmegen experience from 1996 to 2008. Otol Neurotol 2010;31:615–623.

28Ho EC, Monksfield P, Egan E, Reid A, Proops D: Bilateral bone-anchored hearing aid: impact on quality of life measured with the Glasgow benefit Inventory. Otol Neurotol 2009;30:891–896.

29Dutt SN, McDermott AL, Burrell SP, Cooper HR, Reid AP, Proops DW: Patient satisfaction with bilateral bone-anchored hearing aids: the Birmingham experience. J Laryngol Otol Suppl 2002;37–46.

30Deas RW, Adamson RB, Curran LL, Makki FM, Bance M, Brown J: Audiometric thresholds measured with single and dual BAHA transducers: the effect of phase inversion. Int J Audiol 2010;49:933–939.

31Liao C: Application of cross-talk cancellation to the improvement of binaural directional properties for individuals using bone anchored hearing aids (BAHA). 2010.

32Dimmelow KL, Fitzgerald O’Connor A, Johnson IJ, McKinney C, Mendelow AD, Shackleton C: Hear the other side – a report on Single Sided Deafness. Consultant 2003;1–20.

33Wazen JJ, Spitzer JB, Ghossaini SN, Fayad JN, Niparko JK, Cox K, et al: Transcranial contralateral cochlear stimulation in unilateral deafness. Otolaryngol Head Neck Surg 2003;129:248–254.

34Agterberg MJ, Hol MK, van Wanrooij MM, van Opstal AJ, Snik AF: Single-sided deafness and directional hearing: contribution of spectral cues and high-frequency hearing loss in the hearing ear. Front Neurosci 2014;8:1–8.

35Lieu JE: Unilateral hearing loss in children: speech-language and school performance. B-ENT 2013;(suppl 21):107–115.

36Schmithorst VJ, Plante E, Holland S: Unilateral deafness in children affects development of multi-modal modulation and default mode networks. Front Hum Neurosci 2014;8:164.

37Pai I, Kelleher C, Nunn T, Pathak N, Jindal M, O’Connor AF, et al: Outcome of bone-anchored hearing aids for single-sided deafness: a prospective study. Acta Otolaryngol 2012;132:751–755.

38Bovo R, Prosser S, Ortore RP, Martini A: Speech recognition with BAHA simulator in subjects with acquired unilateral sensorineural hearing loss. Acta Otolaryngol 2011;131:633–639.

39Peters JPM, Smit AL, Stegeman I, Grolman W: Review: Bone conduction devices and contralateral routing of sound systems in single-sided deafness. Laryngoscope 2015;125:218–226.

40Linstrom CJ, Silverman CA, Yu GP: Efficacy of the bone-anchored hearing aid for single-sided deafness. Laryngoscope 2009;119:713–720.

41Yuen HW, Bodmer D, Smilsky K, Nedzelski JM, Chen JM: Management of single-sided deafness with the bone-anchored hearing aid. Otolaryngol Head Neck Surg 2009;141:16–23.

42Dumper J, Hodgetts B, Liu R, Brandner N: Indications for bone-anchored hearing AIDS: a functional outcomes study. J Otolaryngol Head Neck Surg 2009;38:96–105.

43Gluth MB, Eager KM, Eikelboom RH, Atlas MD: Long-term benefit perception, complications, and device malfunction rate of bone-anchored hearing aid implantation for profound unilateral sensorineural hearing loss. Otol Neurotol 2010;31:1427–1434.

44Hol MK, Kunst SJ, Snik AF, Cremers CW: Pilot study on the effectiveness of the conventional CROS, the transcranial CROS and the BAHA transcranial CROS in adults with unilateral inner ear deafness. Eur Arch Otorhinolaryngol 2010;267:889–896.

45Lin LM, Bowditch S, Anderson MJ, May B, Cox KM, Niparko JK: Amplification in the rehabilitation of unilateral deafness: speech in noise and directional hearing effects with bone-anchored hearing and contralateral routing of signal amplification. Otol Neurotol 2006;27:172–182.

46Martin TP, Lowther R, Cooper H, Holder RL, Irving RM, Reid AP, et al: The bone-anchored hearing aid in the rehabilitation of single-sided deafness: experience with 58 patients. Clin Otolaryngol 2010;35:284–290.

47Wolfe J, Neumann S, Marsh M, Schafer E, Lianos L, Gilden J, et al: Benefits of adaptive signal processing in a commercially available cochlear implant sound processor. Otol Neurotol 2015;36:1181–1190.

48Arndt S, Aschendorff A, Laszig R, Beck R, Schild C, Kroeger S, et al: Comparison of pseudobinaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus. Otol Neurotol 2011;32:39–47.

49Wazen JJ, Van Ess MJ, Alameda J, Ortega C, Modisett M, Pinsky K: The Baha system in patients with single-sided deafness and contralateral hearing loss. Otolaryngol Head Neck Surg 2010;142:554–559.

R.W.J. McLeod

School of Psychology, Cardiff University

Tower Building, Park Place

Cardiff, CF10 SAT (UK)

E-Mail mcleodrwj@googlemail.com

Advances in Hearing Rehabilitation

Подняться наверх