Читать книгу Flow-Induced Vibration Handbook for Nuclear and Process Equipment - Группа авторов - Страница 57
2.7.2 Random Turbulence Excitation
ОглавлениеThe vibration response to random turbulence excitation should be sufficiently low to prevent excessive tube wall reduction due to fretting wear. The tube wall fretting‐wear depth, dw, calculated as per Section 2.6.3 for the entire life of the component should be less than a specified percentage of the nominal design tube wall thickness (e.g., 40%).