Читать книгу Flow-Induced Vibration Handbook for Nuclear and Process Equipment - Группа авторов - Страница 58
2.7.3 Periodic Wake Shedding
ОглавлениеResonance due to coincidence of tube frequency and periodic‐wake‐shedding frequency should be avoided. If the latter is not possible, the maximum (zero‐peak) tube vibration amplitude, Ymax, at resonance should be less than two percent of the tube diameter, thus:
(2‐56)
Below 0.02D, the vibration amplitude is generally not sufficient to spatially correlate the formation of vortex shedding with the motion of the tube, thereby resulting in a much‐reduced uncorrelated vibration response.