Vascular injury: dissections
ОглавлениеOCT is a very sensitive tool in detecting micro‐dissections and subclinical dissections [81]. Dissections occur more frequently when the plaque at the edge of the stent is fibro‐calcific or lipid‐rich than when is fibrous [82]. Distal stent edge dissections (>200 μm) in CLI OPCI II Study revealed by OCT emerged as an independent predictor of MACE; minimal dissection, at the edge or instent, were not associated with adverse effects [54].