Читать книгу The ESD Control Program Handbook - Jeremy M. Smallwood - Страница 71
2.6.6 ESD from Charged Cables
ОглавлениеCables and wiring looms can have significant capacitance between the wires in the cable and between the wires and ground. This can be of the order of 100 pFm−1. Wires in the cable can become charged by various means such as by movement of the cable or by removal of the cable from packaging (Figure 2.19). If the cable is connected to equipment in this state, a charged cable ESD event can occur to the first terminal to make a connection (Figure 2.20).