Читать книгу PID Control System Design and Automatic Tuning using MATLAB/Simulink - Liuping Wang - Страница 45

Problems

Оглавление

1 1.1 The following system is given to practice the Ziegler-Nichols tuning rules based on oscillation testing data to determine the PID controller parameters:Build a Simulink simulator using closed-loop proportional control with a controller for the system. The sampling interval is chosen to be 0.1 sec.Find the PI and PID controller parameters using Table 1.1.Implement the PI and PID controllers in Simulink with a step reference signal by putting both proportional and derivative control on the output only.What are your observations with respect to the closed-loop performance of the PI and PID control system?

2 1.2 In the majority of the tuning rules, the key step is to find a first order plus delay approximate model for step response testing data. Because the step response of a first order system () to a unit step input signal can be expressed aswe can determine the time constant using 63.2 percent of the rising time in the step response.Why does the 6.32 percent of the rising time correspond to the time constant ?Construct a graphic method to find a first order plus time delay model for the following system:Compare this first order plus delay model with that found in Example 1.7.Find the PID controller parameters using Table 1.2 and compare the closed-loop simulation results with the ones given in Example 1.7. What are your observations?If the step response data contained severe measurement noise, would it be more difficult to determine the rising time?

3 1.3 The transfer function for the fired heater system with high operating condition introduced in Section 1.5.2 is given as(1.61) Find the first order plus delay approximate model for this transfer function using the graphic method in Section 1.3.2. The sampling interval is chosen to be 1.Determine the PID controllers using Tables 1.21.6.Evaluate their closed-loop performance by simulating their closed-loop unit step responses. What are your observations in terms of closed-loop performance with respect to the tuning rules?

4 1.4 The transfer function for the fired heater system with low operating condition introduced in Section 1.5.2 is given as(1.62) Design three PID controllers for this system using IMC-PID controller design equations shown in (1.47) where the desired closed-loop time constant , 30 and 40 respectively.Evaluate the closed-loop control system performance for the three PID controllers by simulating the closed-loop unit step response with sampling interval sec.What are your observations of the closed-loop performance when the desired closed-loop time constant increases?

5 1.5 The two transfer functions obtained from the fired heater system are drastically different at the two operating conditions (see (1.61)–(1.62)). Hence, the PID controllers are different for the two operating conditions. Assume that we would only use one PID controller for both operating conditions.Design IMC-PID controller () for the fired heater system at high operating condition using with .Evaluate the closed-loop performance by simulating the two PID control systems: (1) and ; (2) and , respectively.Let denote the PID controller found from Problem 1.4 with . Evaluate the closed-loop performance by simulating the two PID control systems: (1) and ; (2) and .Based on the simulation studies, which controller should we recommend?Increase the desired time constant to 40 and repeat the evaluations. What would be the recommendations for the choice of ?