Читать книгу Wind Energy Handbook - Michael Barton Graham - Страница 34

2.6.3 Turbulence intensity

Оглавление

The turbulence intensity in the neutral atmosphere clearly depends on the surface roughness. For the longitudinal component, the standard deviation σu is approximately constant with height, so the turbulence intensity decreases with height. More precisely, the relationship σu ≈ 2.5u* may be used to calculate the standard deviation, with the friction velocity u* calculated as in the previous section. More recent work (ESDU 1985) suggests a variation given by

(2.15)

where

(2.16)

(2.17)

This approximates to σu = 2.5u* close to the ground, but gives larger values at greater heights. The longitudinal turbulence intensity is then

(2.18)

The lateral (v) and vertical (w) turbulence intensities are given (ESDU 1985) by

(2.19)

(2.20)

Note that specific values of turbulence intensity for use in design calculations are prescribed in some of the standards used for wind turbine design calculations, and these may not always correspond with the above expressions. For example, the now superseded Danish standard (DS 472 1992) specified

(2.21)

with Iv = 0.8 Iu and Iw = 0.5 Iu.

The IEC edition 2 standard (IEC 61400‐1 1999) gives

(2.22)

where I15 = 0.18 for ‘higher turbulence sites’ and 0.16 for ‘lower turbulence sites’, with corresponding values of a of 2 and 3, respectively. For the lateral and vertical components, a choice is allowed: either Iv = 0.8 Iu and Iw = 0.5 Iu, or an isotropic model with Iu = Iv = Iw.

Editions 3 (IEC 61400‐1 2005) and 4 (IEC 61400‐1 2019) of the IEC standard specify

(2.23)

where Iref = 0.16, 0.14, or 0.12 depending on the wind class. For lateral and vertical components, Iv must be at least 0.7Iu, and Iw at least 0.5Iu. Standard deviations are assumed constant with height, so the turbulence intensity will change with height as the mean wind speed changes due to wind shear.

The earlier GL rules (GL 1993) simply specified 20% turbulence intensity, but the later edition (GL 2003) follows IEC edition 2.

Figure 2.4 shows example longitudinal turbulence intensities for the GL, IEC, and Danish standards. The low value for the Danish standard is for 90 m height with roughness length 0.01 m; the high value is for 30 m height with roughness length 0.3 m. The high values for IEC editions 2, 3, and 4 are the same, but the low value is significantly lower in editions 3 and 4 than in edition 2.


Figure 2.4 Turbulence intensities according to various standards