Читать книгу Continuous Emission Monitoring - James A. Jahnke - Страница 71

Level 4

Оглавление

This level of activity determines the source performance with respect to the compliance test methods. If the tests show that the source is not in compliance with emissions limits, the test data can be used to support further legal action.

The following potential violations (among others) may be indicated from an excess emission report, supplementary information accompanying the report, or information requested upon the review (VADEQ 2018; U.S. EPA 2014c):

 Exceeding the emission limit

 Failure to meet emission control percentage reduction requirement

 Failure to meet monitoring availability specification (as applicable in rule or permit)

 Control equipment operation and maintenance deficiencies

 Failure to conduct required, periodic CEM performance evaluations (RATAs, CGAs, Linearity Tests)

 Failure to write or implement a CEM system QA/QC Plan

 Failure to follow permit recordkeeping and reporting requirements

Continuous Emission Monitoring