2.1.3.2 Measurements
ОглавлениеSeveral investigators have measured the power density distribution (and current density distribution) in the gas−tungsten arc by using the split‐anode method [318–20]. Figure 2.13 shows the results of Tsai [20] and Lu and Kou [3], which can be represented by the Gaussian‐type distribution [21–23].
Figure 2.13 Measured power density distributions.
Source: Lu and Kou [3]. Welding Journal, February 1988, © American Welding Society.